HRS Series Electric Actuation for Hazardous Locations - ATEX

Dev logs

All Files

        Array
(
    [0] => HXBSN4E_4F_3_Phase_IOM_EN:akeneo_connector/asset_files/H/X/HXBSN4E_4F_3_Phase_IOM_EN_566f.pdf
    [1] => HXBSN4E_4F_3_Phase_DataSheet_EN:akeneo_connector/asset_files/H/X/HXBSN4E_4F_3_Phase_DataSheet_EN_f138.pdf
)
    

Electrodes

        Array
(
)
    

Electrodes Tabs

        Array
(
)
    

Datasheet

        Array
(
    [0] => Array
        (
            [0] => HXBSN3A_3B_3_Phase_DataSheet_EN
            [1] => akeneo_connector/asset_files/H/X/HXBSN3A_3B_3_Phase_DataSheet_EN_f000.pdf
        )

    [1] => Array
        (
            [0] => HXBSN4A_4D_3_Phase_DataSheet_EN
            [1] => akeneo_connector/asset_files/H/X/HXBSN4A_4D_3_Phase_DataSheet_EN_cec8.pdf
        )

    [2] => Array
        (
            [0] => HXBSN3A_3B_DataSheet_EN
            [1] => akeneo_connector/asset_files/H/X/HXBSN3A_3B_DataSheet_EN_f76a.pdf
        )

    [3] => Array
        (
            [0] => HXC2B_HXC2S_DataSheet_EN
            [1] => akeneo_connector/asset_files/H/X/HXC2B_HXC2S_DataSheet_EN_6102.pdf
        )

    [4] => Array
        (
            [0] => HXBSN4A_4D_DataSheet_EN
            [1] => akeneo_connector/asset_files/H/X/HXBSN4A_4D_DataSheet_EN_2020.pdf
        )

    [5] => Array
        (
            [0] => HXBSN4E_4F_DataSheet_EN
            [1] => akeneo_connector/asset_files/H/X/HXBSN4E_4F_DataSheet_EN_6c88.pdf
        )

    [6] => Array
        (
            [0] => HXBSN4E_4F_3_Phase_DataSheet_EN
            [1] => akeneo_connector/asset_files/H/X/HXBSN4E_4F_3_Phase_DataSheet_EN_f138.pdf
        )

)
    

Brochures tab

        Array
(
    [0] => Array
        (
            [0] => Hayward_Comprehensive_Actuation_Guide_ProductGuide_EN
            [1] => akeneo_connector/asset_files/H/a/Hayward_Comprehensive_Actuation_Guide_ProductGuide_EN_9c73.pdf
        )

    [1] => Array
        (
            [0] => HXBSN3A_3B_3_Phase_DataSheet_EN
            [1] => akeneo_connector/asset_files/H/X/HXBSN3A_3B_3_Phase_DataSheet_EN_f000.pdf
        )

    [2] => Array
        (
            [0] => HXBSN4A_4D_3_Phase_DataSheet_EN
            [1] => akeneo_connector/asset_files/H/X/HXBSN4A_4D_3_Phase_DataSheet_EN_cec8.pdf
        )

    [3] => Array
        (
            [0] => HXBSN3A_3B_DataSheet_EN
            [1] => akeneo_connector/asset_files/H/X/HXBSN3A_3B_DataSheet_EN_f76a.pdf
        )

    [4] => Array
        (
            [0] => HXC2B_HXC2S_DataSheet_EN
            [1] => akeneo_connector/asset_files/H/X/HXC2B_HXC2S_DataSheet_EN_6102.pdf
        )

    [5] => Array
        (
            [0] => HXBSN4A_4D_DataSheet_EN
            [1] => akeneo_connector/asset_files/H/X/HXBSN4A_4D_DataSheet_EN_2020.pdf
        )

    [6] => Array
        (
            [0] => HXBSN4E_4F_DataSheet_EN
            [1] => akeneo_connector/asset_files/H/X/HXBSN4E_4F_DataSheet_EN_6c88.pdf
        )

    [7] => Array
        (
            [0] => HXBSN4E_4F_3_Phase_DataSheet_EN
            [1] => akeneo_connector/asset_files/H/X/HXBSN4E_4F_3_Phase_DataSheet_EN_f138.pdf
        )

)
    

0

        Array
(
    [Description] => Array
        (
            [0] => Hayward’s HRXC & HRXB Series electric actuators are designed and produced to provide years of service in demanding industrial environments such as chemical processing, waste and water treatment, power generation, oil & gas, marine, mining and building services. The HRXB/C Series have enhanced housings designed to meet the rigors of operating in explosive atmospheres. These quarter-turn units drive dampers, ball valves, butterfly valves or inlet guide vanes that require torque ranges from 300lbf-in through 20,350 lbf-in.

The HRXB/C Series housings are designed to meet NEMA 4X environmental demands, with ISO5211 compliant mounting that readily attaches to most valves in the industries served. The HRXC Series is a compact multi-stage gear train with a lever-less manual override system built-in. The HRXB Series features an epicyclic transmission system that provides highly efficient multiplication of motor power to produce uniquely compact torque ranges compared to other technologies. A clutch-free manual override system provides full-time override capabilities during powered or un-powered events. 
        )

    [Features] => Array
        (
            [0] => • Designed for use in hazardous locations
• 120VAC, 24VAC/VDC, 230VAC, 220/3, 380/3, 480/3, and 575/3 options available
• Units equipped with two (2) volt-free Form A Auxiliary switches
Anti-Condensate heater standard
• ISO5211 compliant mechanical mount w/ double-square female drive socket
• Two (2) 1/2” or 3/4" EMT ports for ease of field wiring
• NEMA 4/4X/IP66 Compliant
• Visual position indicator
• Collapsible spinner handle
        )

    [Brochures] => Array
        (
            [0] => Array
                (
                    [0] => Hayward_Comprehensive_Actuation_Guide_ProductGuide_EN
                    [1] => akeneo_connector/asset_files/H/a/Hayward_Comprehensive_Actuation_Guide_ProductGuide_EN_9c73.pdf
                )

            [1] => Array
                (
                    [0] => HXBSN3A_3B_3_Phase_DataSheet_EN
                    [1] => akeneo_connector/asset_files/H/X/HXBSN3A_3B_3_Phase_DataSheet_EN_f000.pdf
                )

            [2] => Array
                (
                    [0] => HXBSN4A_4D_3_Phase_DataSheet_EN
                    [1] => akeneo_connector/asset_files/H/X/HXBSN4A_4D_3_Phase_DataSheet_EN_cec8.pdf
                )

            [3] => Array
                (
                    [0] => HXBSN3A_3B_DataSheet_EN
                    [1] => akeneo_connector/asset_files/H/X/HXBSN3A_3B_DataSheet_EN_f76a.pdf
                )

            [4] => Array
                (
                    [0] => HXC2B_HXC2S_DataSheet_EN
                    [1] => akeneo_connector/asset_files/H/X/HXC2B_HXC2S_DataSheet_EN_6102.pdf
                )

            [5] => Array
                (
                    [0] => HXBSN4A_4D_DataSheet_EN
                    [1] => akeneo_connector/asset_files/H/X/HXBSN4A_4D_DataSheet_EN_2020.pdf
                )

            [6] => Array
                (
                    [0] => HXBSN4E_4F_DataSheet_EN
                    [1] => akeneo_connector/asset_files/H/X/HXBSN4E_4F_DataSheet_EN_6c88.pdf
                )

            [7] => Array
                (
                    [0] => HXBSN4E_4F_3_Phase_DataSheet_EN
                    [1] => akeneo_connector/asset_files/H/X/HXBSN4E_4F_3_Phase_DataSheet_EN_f138.pdf
                )

        )

    [Manuals] => Array
        (
            [0] => Array
                (
                    [0] => HXBSN3A_3B_3_Phase_IOM_EN
                    [1] => akeneo_connector/asset_files/H/X/HXBSN3A_3B_3_Phase_IOM_EN_d32e.pdf
                )

            [1] => Array
                (
                    [0] => HXBSN4A_4D_3_Phase_IOM_EN
                    [1] => akeneo_connector/asset_files/H/X/HXBSN4A_4D_3_Phase_IOM_EN_382d.pdf
                )

            [2] => Array
                (
                    [0] => HXBSN3A_3B_IOM_EN
                    [1] => akeneo_connector/asset_files/H/X/HXBSN3A_3B_IOM_EN_3587.pdf
                )

            [3] => Array
                (
                    [0] => HXC2B_HXC2S_IOM_EN
                    [1] => akeneo_connector/asset_files/H/X/HXC2B_HXC2S_IOM_EN_0696.pdf
                )

            [4] => Array
                (
                    [0] => HXBSN4A_4D_IOM_EN
                    [1] => akeneo_connector/asset_files/H/X/HXBSN4A_4D_IOM_EN_b720.pdf
                )

            [5] => Array
                (
                    [0] => HXBSN4E_4F_IOM_EN
                    [1] => akeneo_connector/asset_files/H/X/HXBSN4E_4F_IOM_EN_92ab.pdf
                )

            [6] => Array
                (
                    [0] => HXBSN4E_4F_3_Phase_IOM_EN
                    [1] => akeneo_connector/asset_files/H/X/HXBSN4E_4F_3_Phase_IOM_EN_566f.pdf
                )

        )

    [Parts] => 
    [Accessories] => 
    [Applications] => Array
        (
        )

    [Analytical Electrodes] => Array
        (
        )

)
    

Analytical Electrodes

        Array
(
    [Description] => Array
        (
            [0] => Hayward’s HRXC & HRXB Series electric actuators are designed and produced to provide years of service in demanding industrial environments such as chemical processing, waste and water treatment, power generation, oil & gas, marine, mining and building services. The HRXB/C Series have enhanced housings designed to meet the rigors of operating in explosive atmospheres. These quarter-turn units drive dampers, ball valves, butterfly valves or inlet guide vanes that require torque ranges from 300lbf-in through 20,350 lbf-in.

The HRXB/C Series housings are designed to meet NEMA 4X environmental demands, with ISO5211 compliant mounting that readily attaches to most valves in the industries served. The HRXC Series is a compact multi-stage gear train with a lever-less manual override system built-in. The HRXB Series features an epicyclic transmission system that provides highly efficient multiplication of motor power to produce uniquely compact torque ranges compared to other technologies. A clutch-free manual override system provides full-time override capabilities during powered or un-powered events. 
        )

    [Features] => Array
        (
            [0] => • Designed for use in hazardous locations
• 120VAC, 24VAC/VDC, 230VAC, 220/3, 380/3, 480/3, and 575/3 options available
• Units equipped with two (2) volt-free Form A Auxiliary switches
Anti-Condensate heater standard
• ISO5211 compliant mechanical mount w/ double-square female drive socket
• Two (2) 1/2” or 3/4" EMT ports for ease of field wiring
• NEMA 4/4X/IP66 Compliant
• Visual position indicator
• Collapsible spinner handle
        )

    [Brochures] => Array
        (
            [0] => Array
                (
                    [0] => Hayward_Comprehensive_Actuation_Guide_ProductGuide_EN
                    [1] => akeneo_connector/asset_files/H/a/Hayward_Comprehensive_Actuation_Guide_ProductGuide_EN_9c73.pdf
                )

            [1] => Array
                (
                    [0] => HXBSN3A_3B_3_Phase_DataSheet_EN
                    [1] => akeneo_connector/asset_files/H/X/HXBSN3A_3B_3_Phase_DataSheet_EN_f000.pdf
                )

            [2] => Array
                (
                    [0] => HXBSN4A_4D_3_Phase_DataSheet_EN
                    [1] => akeneo_connector/asset_files/H/X/HXBSN4A_4D_3_Phase_DataSheet_EN_cec8.pdf
                )

            [3] => Array
                (
                    [0] => HXBSN3A_3B_DataSheet_EN
                    [1] => akeneo_connector/asset_files/H/X/HXBSN3A_3B_DataSheet_EN_f76a.pdf
                )

            [4] => Array
                (
                    [0] => HXC2B_HXC2S_DataSheet_EN
                    [1] => akeneo_connector/asset_files/H/X/HXC2B_HXC2S_DataSheet_EN_6102.pdf
                )

            [5] => Array
                (
                    [0] => HXBSN4A_4D_DataSheet_EN
                    [1] => akeneo_connector/asset_files/H/X/HXBSN4A_4D_DataSheet_EN_2020.pdf
                )

            [6] => Array
                (
                    [0] => HXBSN4E_4F_DataSheet_EN
                    [1] => akeneo_connector/asset_files/H/X/HXBSN4E_4F_DataSheet_EN_6c88.pdf
                )

            [7] => Array
                (
                    [0] => HXBSN4E_4F_3_Phase_DataSheet_EN
                    [1] => akeneo_connector/asset_files/H/X/HXBSN4E_4F_3_Phase_DataSheet_EN_f138.pdf
                )

        )

    [Manuals] => Array
        (
            [0] => Array
                (
                    [0] => HXBSN3A_3B_3_Phase_IOM_EN
                    [1] => akeneo_connector/asset_files/H/X/HXBSN3A_3B_3_Phase_IOM_EN_d32e.pdf
                )

            [1] => Array
                (
                    [0] => HXBSN4A_4D_3_Phase_IOM_EN
                    [1] => akeneo_connector/asset_files/H/X/HXBSN4A_4D_3_Phase_IOM_EN_382d.pdf
                )

            [2] => Array
                (
                    [0] => HXBSN3A_3B_IOM_EN
                    [1] => akeneo_connector/asset_files/H/X/HXBSN3A_3B_IOM_EN_3587.pdf
                )

            [3] => Array
                (
                    [0] => HXC2B_HXC2S_IOM_EN
                    [1] => akeneo_connector/asset_files/H/X/HXC2B_HXC2S_IOM_EN_0696.pdf
                )

            [4] => Array
                (
                    [0] => HXBSN4A_4D_IOM_EN
                    [1] => akeneo_connector/asset_files/H/X/HXBSN4A_4D_IOM_EN_b720.pdf
                )

            [5] => Array
                (
                    [0] => HXBSN4E_4F_IOM_EN
                    [1] => akeneo_connector/asset_files/H/X/HXBSN4E_4F_IOM_EN_92ab.pdf
                )

            [6] => Array
                (
                    [0] => HXBSN4E_4F_3_Phase_IOM_EN
                    [1] => akeneo_connector/asset_files/H/X/HXBSN4E_4F_3_Phase_IOM_EN_566f.pdf
                )

        )

    [Parts] => 
    [Accessories] => 
    [Applications] => Array
        (
        )

    [Analytical Electrodes] => Array
        (
        )

)
    
        Array
(
)
    

Hayward’s HRXC & HRXB Series electric actuators are designed and produced to provide years of service in demanding industrial environments such as chemical processing, waste and water treatment, power generation, oil & gas, marine, mining and building services. The HRXB/C Series have enhanced housings designed to meet the rigors of operating in explosive atmospheres. These quarter-turn units drive dampers, ball valves, butterfly valves or inlet guide vanes that require torque ranges from 300lbf-in through 20,350 lbf-in. The HRXB/C Series housings are designed to meet NEMA 4X environmental demands, with ISO5211 compliant mounting that readily attaches to most valves in the industries served. The HRXC Series is a compact multi-stage gear train with a lever-less manual override system built-in. The HRXB Series features an epicyclic transmission system that provides highly efficient multiplication of motor power to produce uniquely compact torque ranges compared to other technologies. A clutch-free manual override system provides full-time override capabilities during powered or un-powered events.

Key Features and Benefits

•   Designed for use in hazardous locations
•   120VAC, 24VAC/VDC, 230VAC, 220/3, 380/3, 480/3, and 575/3 options available
•   Units equipped with two (2) volt-free Form A Auxiliary switches Anti-Condensate heater standard
•   ISO5211 compliant mechanical mount w/ double-square female drive socket
•   Two (2) 1/2” or 3/4" EMT ports for ease of field wiring
•   NEMA 4/4X/IP66 Compliant
•   Visual position indicator
•   Collapsible spinner handle
Item # Voltage Torque Rating Control Chassis Power Type CAD/BIM Available
HXBSN3BT1DATTM3 HXB3B 1770 in/lbs 480 On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 480VAC 3-Phase 1770 in*lbs On/Off HXB3B 3 Phase
HXBSN3AM8DACTM3 HXB3A 880 in/lbs 220V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 230VAC 3-Phase 880 in*lbs 4-20mA In/Out HXB3A 3 Phase
HXBSN4CT1FATTM3 HXB4C 7080 in/lbs 480 On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 480VAC 3-Phase 7080 in*lbs On/Off HXB4C 3 Phase
HXBSN3BE1DAN0T HXB3B 1770 in/lbs 24V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 24VAC/VDC 1770 in*lbs On/Off HXB3B AC/DC
HXCSN2BE1BAN00 HXC2B 310 in/lbs 24V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 24VAC/VDC 310 in*lbs On/Off HXC2B AC/DC
HXBSN4BT8FACTM3 HXB4B 5310 in/lbs 480 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 480VAC 3-Phase 5310 in*lbs 4-20mA In/Out HXB4B 3 Phase
HXBSN4DL8FAC0T HXB4D 8850 in/lbs 230/VAC 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 220~240VAC 8850 in*lbs 4-20mA In/Out HXB4D AC
HXBSN4DM8FACTM3 HXB4D 8850 in/lbs 220V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 230VAC 3-Phase 8850 in*lbs 4-20mA In/Out HXB4D 3 Phase
HXCSN2SK1BAT00 HXC2S 440 in/lbs 120V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 110~120VAC 440 in*lbs On/Off HXC2S AC
HXBSN4FK1HAT0T HXB4F 20350 in/lbs 120V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 110~120VAC 20350 in*lbs On/Off HXB4F AC
HXBSN3BK1DAT0T HXB3B 1770 in/lbs 120V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 110~120VAC 1770 in*lbs On/Off HXB3B AC
HXBSN4FM1HATTM3 HXB4F 20350 in/lbs 220V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 230VAC 3-Phase 20350 in*lbs On/Off HXB4F 3 Phase
HXBSN3AE1DAN0T HXB3A 880 in/lbs 24V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 24VAC/VDC 880 in*lbs On/Off HXB3A AC/DC
HXBSN4CL8FAC0T HXB4C 7080 in/lbs 230/VAC 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 220~240VAC 7080 in*lbs 4-20mA In/Out HXB4C AC
HXBSN4BM8FACTM3 HXB4B 5310 in/lbs 220V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 230VAC 3-Phase 5310 in*lbs 4-20mA In/Out HXB4B 3 Phase
HXBSN4EE8GAC0T HXB4E 15040 in/lbs 24V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 24VAC/VDC 15040 in*lbs 4-20mA In/Out HXB4E AC/DC
HXBSN4BL1FAT0T HXB4B 5310 in/lbs 230/VAC On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 220~240VAC 5310 in*lbs On/Off HXB4B AC
HXBSN3BE8DAC0T HXB3B 1770 in/lbs 24V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 24VAC/VDC 1770 in*lbs 4-20mA In/Out HXB3B AC/DC
HXCSN2BK8BAC00 HXC2B 310 in/lbs 120V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 110~120VAC 310 in*lbs 4-20mA In/Out HXC2B AC
HXBSN4EE1GAN0T HXB4E 15040 in/lbs 24V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 24VAC/VDC 15040 in*lbs On/Off HXB4E AC/DC
HXBSN4EK8GAC0T HXB4E 15040 in/lbs 120V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 110~120VAC 15040 in*lbs 4-20mA In/Out HXB4E AC
HXCSN2SE8BAC00 HXC2S 440 in/lbs 24V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 24VAC/VDC 440 in*lbs 4-20mA In/Out HXC2S AC/DC
HXBSN4EL8GAC0T HXB4E 15040 in/lbs 230/VAC 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 220~240VAC 15040 in*lbs 4-20mA In/Out HXB4E AC
HXBSN3BL1DAT0T HXB3B 1770 in/lbs 230/VAC On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 220~240VAC 1770 in*lbs On/Off HXB3B AC
HXBSN3AE8DAC0T HXB3A 880 in/lbs 24V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 24VAC/VDC 880 in*lbs 4-20mA In/Out HXB3A AC/DC
HXBSN3AT8DACTM3 HXB3A 880 in/lbs 480 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 480VAC 3-Phase 880 in*lbs 4-20mA In/Out HXB3A 3 Phase
HXCSN2SL8BAC00 HXC2S 440 in/lbs 230/VAC 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 220~240VAC 440 in*lbs 4-20mA In/Out HXC2S AC
HXBSN4EM8GACTM3 HXB4E 15040 in/lbs 220V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 230VAC 3-Phase 15040 in*lbs 4-20mA In/Out HXB4E 3 Phase
HXBSN4DK1FAT0T HXB4D 8850 in/lbs 120V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 110~120VAC 8850 in*lbs On/Off HXB4D AC
HXBSN4BT1FATTM3 HXB4B 5310 in/lbs 480 On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 480VAC 3-Phase 5310 in*lbs On/Off HXB4B 3 Phase
HXBSN4CL1FAT0T HXB4C 7080 in/lbs 230/VAC On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 220~240VAC 7080 in*lbs On/Off HXB4C AC
HXBSN4EM1GATTM3 HXB4E 15040 in/lbs 220V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 230VAC 3-Phase 15040 in*lbs On/Off HXB4E 3 Phase
HXBSN4CT8FACTM3 HXB4C 7080 in/lbs 480 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 480VAC 3-Phase 7080 in*lbs 4-20mA In/Out HXB4C 3 Phase
HXBSN4CM8FACTM3 HXB4C 7080 in/lbs 220V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 230VAC 3-Phase 7080 in*lbs 4-20mA In/Out HXB4C 3 Phase
HXBSN4AT1EATTM3 HXB4A 3540 in/lbs 480 On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 480VAC 3-Phase 3540 in*lbs On/Off HXB4A 3 Phase
HXBSN3BT8DACTM3 HXB3B 1770 in/lbs 480 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 480VAC 3-Phase 1770 in*lbs 4-20mA In/Out HXB3B 3 Phase
HXBSN4CK1FAT0T HXB4C 7080 in/lbs 120V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 110~120VAC 7080 in*lbs On/Off HXB4C AC
HXBSN4CK8FAC0T HXB4C 7080 in/lbs 120V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 110~120VAC 7080 in*lbs 4-20mA In/Out HXB4C AC
HXBSN3AK8DAC0T HXB3A 880 in/lbs 120V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 110~120VAC 880 in*lbs 4-20mA In/Out HXB3A AC
HXCSN2BL1BAT00 HXC2B 310 in/lbs 230/VAC On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 220~240VAC 310 in*lbs On/Off HXC2B AC
HXBSN3AL1DAT0T HXB3A 880 in/lbs 230/VAC On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 220~240VAC 880 in*lbs On/Off HXB3A AC
HXBSN4FM8HACTM3 HXB4F 20350 in/lbs 220V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 230VAC 3-Phase 20350 in*lbs 4-20mA In/Out HXB4F 3 Phase
HXBSN4DE1FAN0T HXB4D 8850 in/lbs 24V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 24VAC/VDC 8850 in*lbs On/Off HXB4D AC/DC
HXCSN2SE1BAN00 HXC2S 440 in/lbs 24V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 24VAC/VDC 440 in*lbs On/Off HXC2S AC/DC
HXBSN4AT8EACTM3 HXB4A 3540 in/lbs 480 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 480VAC 3-Phase 3540 in*lbs 4-20mA In/Out HXB4A 3 Phase
HXBSN4DK8FAC0T HXB4D 8850 in/lbs 120V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 110~120VAC 8850 in*lbs 4-20mA In/Out HXB4D AC
HXBSN3BM1DATTM3 HXB3B 1770 in/lbs 220V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 230VAC 3-Phase 1770 in*lbs On/Off HXB3B 3 Phase
HXBSN3AT1DATTM3 HXB3A 880 in/lbs 480 On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 480VAC 3-Phase 880 in*lbs On/Off HXB3A 3 Phase
HXBSN4AM8EACTM3 HXB4A 3540 in/lbs 220V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 230VAC 3-Phase 3540 in*lbs 4-20mA In/Out HXB4A 3 Phase
HXBSN4FL8HAC0T HXB4F 20350 in/lbs 230/VAC 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 220~240VAC 20350 in*lbs 4-20mA In/Out HXB4F AC
HXBSN4DT8FACTM3 HXB4D 8850 in/lbs 480 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 480VAC 3-Phase 8850 in*lbs 4-20mA In/Out HXB4D 3 Phase
HXBSN4BK8FAC0T HXB4B 5310 in/lbs 120V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 110~120VAC 5310 in*lbs 4-20mA In/Out HXB4B AC
HXBSN3AK1DAT0T HXB3A 880 in/lbs 120V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 110~120VAC 880 in*lbs On/Off HXB3A AC
HXBSN4DE8FAC0T HXB4D 8850 in/lbs 24V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 24VAC/VDC 8850 in*lbs 4-20mA In/Out HXB4D AC/DC
HXBSN4EK1GAT0T HXB4E 15040 in/lbs 120V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 110~120VAC 15040 in*lbs On/Off HXB4E AC
HXBSN4AK1EAT0T HXB4A 3540 in/lbs 120V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 110~120VAC 3540 in*lbs On/Off HXB4A AC
HXBSN4DM1FATTM3 HXB4D 8850 in/lbs 220V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 230VAC 3-Phase 8850 in*lbs On/Off HXB4D 3 Phase
HXCSN2BE8BAC00 HXC2B 310 in/lbs 24V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 24VAC/VDC 310 in*lbs 4-20mA In/Out HXC2B AC/DC
HXBSN4BL8FAC0T HXB4B 5310 in/lbs 230/VAC 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 220~240VAC 5310 in*lbs 4-20mA In/Out HXB4B AC
HXBSN4FL1HAT0T HXB4F 20350 in/lbs 230/VAC On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 220~240VAC 20350 in*lbs On/Off HXB4F AC
HXCSN2BL8BAC00 HXC2B 310 in/lbs 230/VAC 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 220~240VAC 310 in*lbs 4-20mA In/Out HXC2B AC
HXBSN3AM1DATTM3 HXB3A 880 in/lbs 220V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 230VAC 3-Phase 880 in*lbs On/Off HXB3A 3 Phase
HXBSN3BK8DAC0T HXB3B 1770 in/lbs 120V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 110~120VAC 1770 in*lbs 4-20mA In/Out HXB3B AC
HXBSN4DL1FAT0T HXB4D 8850 in/lbs 230/VAC On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 220~240VAC 8850 in*lbs On/Off HXB4D AC
HXBSN4CM1FATTM3 HXB4C 7080 in/lbs 220V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 230VAC 3-Phase 7080 in*lbs On/Off HXB4C 3 Phase
HXBSN4FT8HACTM3 HXB4F 20350 in/lbs 480 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 480VAC 3-Phase 20350 in*lbs 4-20mA In/Out HXB4F 3 Phase
HXBSN4AM1EATTM3 HXB4A 3540 in/lbs 220V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 230VAC 3-Phase 3540 in*lbs On/Off HXB4A 3 Phase
HXBSN4BE8FAC0T HXB4B 5310 in/lbs 24V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 24VAC/VDC 5310 in*lbs 4-20mA In/Out HXB4B AC/DC
HXBSN4DT1FATTM3 HXB4D 8850 in/lbs 480 On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 480VAC 3-Phase 8850 in*lbs On/Off HXB4D 3 Phase
HXBSN4FK8HAC0T HXB4F 20350 in/lbs 120V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 110~120VAC 20350 in*lbs 4-20mA In/Out HXB4F AC
HXBSN3AL8DAC0T HXB3A 880 in/lbs 230/VAC 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 220~240VAC 880 in*lbs 4-20mA In/Out HXB3A AC
HXCSN2BK1BAT00 HXC2B 310 in/lbs 120V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 110~120VAC 310 in*lbs On/Off HXC2B AC
HXBSN4BK1FAT0T HXB4B 5310 in/lbs 120V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 110~120VAC 5310 in*lbs On/Off HXB4B AC
HXBSN4CE8FAC0T HXB4C 7080 in/lbs 24V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 24VAC/VDC 7080 in*lbs 4-20mA In/Out HXB4C AC/DC
HXBSN4EL1GAT0T HXB4E 15040 in/lbs 230/VAC On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 220~240VAC 15040 in*lbs On/Off HXB4E AC
HXBSN4BM1FATTM3 HXB4B 5310 in/lbs 220V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 230VAC 3-Phase 5310 in*lbs On/Off HXB4B 3 Phase
HXBSN3BL8DAC0T HXB3B 1770 in/lbs 230/VAC 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 220~240VAC 1770 in*lbs 4-20mA In/Out HXB3B AC
HXBSN4ET1GATTM3 HXB4E 15040 in/lbs 480 On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 480VAC 3-Phase 15040 in*lbs On/Off HXB4E 3 Phase
HXCSN2SK8BAC00 HXC2S 440 in/lbs 120V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 110~120VAC 440 in*lbs 4-20mA In/Out HXC2S AC
HXBSN4CE1FAN0T HXB4C 7080 in/lbs 24V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 24VAC/VDC 7080 in*lbs On/Off HXB4C AC/DC
HXBSN4AE1EAN0T HXB4A 3540 in/lbs 24V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 24VAC/VDC 3540 in*lbs On/Off HXB4A AC/DC
HXBSN4AK8EAC0T HXB4A 3540 in/lbs 120V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 110~120VAC 3540 in*lbs 4-20mA In/Out HXB4A AC
HXBSN4ET8GACTM3 HXB4E 15040 in/lbs 480 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 480VAC 3-Phase 15040 in*lbs 4-20mA In/Out HXB4E 3 Phase
HXBSN4AE8EAC0T HXB4A 3540 in/lbs 24V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 24VAC/VDC 3540 in*lbs 4-20mA In/Out HXB4A AC/DC
HXBSN4FT1HATTM3 HXB4F 20350 in/lbs 480 On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 480VAC 3-Phase 20350 in*lbs On/Off HXB4F 3 Phase
HXCSN2SL1BAT00 HXC2S 440 in/lbs 230/VAC On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 220~240VAC 440 in*lbs On/Off HXC2S AC
HXBSN4BE1FAN0T HXB4B 5310 in/lbs 24V On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 24VAC/VDC 5310 in*lbs On/Off HXB4B AC/DC
HXBSN4AL8EAC0T HXB4A 3540 in/lbs 230/VAC 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 220~240VAC 3540 in*lbs 4-20mA In/Out HXB4A AC
HXBSN3BM8DACTM3 HXB3B 1770 in/lbs 220V 4/20mA/In/Out NEMA/4/4X/IP66 Hazardous/Location/ATEX 230VAC 3-Phase 1770 in*lbs 4-20mA In/Out HXB3B 3 Phase
HXBSN4AL1EAT0T HXB4A 3540 in/lbs 230/VAC On/Off NEMA/4/4X/IP66 Hazardous/Location/ATEX 220~240VAC 3540 in*lbs On/Off HXB4A AC